Accepted items
These items are already registered.
Your upload file is ready. But EUDAMED rejects individual items. What does the error code mean? And which data do you need to correct now?
Here you will find causes and suitable solutions when a file violates the schema or the business rules. So you know exactly how to continue.
Recreated excerpt, sample data
Rejections are part of uploading. The validation rules are spread across the schema, business rules and guidelines. The business rules for product data alone run to 27 pages. Search for the code from your response file or for a keyword.
Try a different search term or have your error message checked.
| What EUDAMED reports | Cause | Solution |
|---|---|---|
| File not validRules BR-DTX-EUD-103 and BR-DTX-EUD-104 | The XML file does not match the XSD (XML Schema Definition, the technical template against which EUDAMED checks every file). Typical causes are values outside the code list, empty mandatory fields or elements in the wrong order. | Check the file against the current schema before uploading. The schema version in the file header must match the current EUDAMED version. |
| File too largeRule BR-DTX-EUD-021 | A maximum of 300 entries is allowed per message. The XML file in the ZIP archive may be no larger than 1 MB. | Split the items across several files with a maximum of 300 entries each. |
| Wrong service selectedERR-DTX-EUD-103.03-02 From upload sessions | A different service was selected under “Select a service” than the file requires. The service names are similar. | For each file, note the exact name of the service and the order of the uploads. |
| No authorisationRules BR-DTX-UDI-079 and BR-DTX-EUD-106 | Only users assigned to the manufacturer in EUDAMED may register products. The local actor administrator enables the services for data exchange. | Check your user role and have your company’s administrator enable the required services. |
| What EUDAMED reports | Cause | Solution |
|---|---|---|
| Code already exists or wrong formatRule BR-UDID-003 | Every code must be unique: Basic UDI-DI, UDI-DI and packaging DI. For GS1 codes, EUDAMED also checks the format including the check digit. In our sessions, the code sometimes already existed as a draft in EUDAMED From upload sessions or the same GTIN (Global Trade Item Number, the item number from GS1) had been assigned twice. | Compare your item list with the download from EUDAMED before uploading. Remove duplicates and check the check digits. |
| New Basic UDI-DI without UDI-DIRule BR-UDID-004 | A new Basic UDI-DI must be submitted together with at least one UDI-DI. | Send the Basic UDI-DI and the first UDI-DI in one entry. |
| Additional UDI-DI not possibleRule BR-UDID-268 | An additional UDI-DI, for example for a new size, can only be added to a Basic UDI-DI with the status “Submitted” or “Registered”. | Submit the Basic UDI-DI first. Then send the additional UDI-DIs via the separate service for additional UDI-DIs. |
| Multiple Basic UDI-DIsRule BR-UDID-069 | Each UDI-DI belongs to exactly one Basic UDI-DI. | Check the assignment in your item list. |
| Trade name without languageRule BR-UDID-070 | Every trade name requires a language. | Add the language for every trade name. |
| Authorised representative missingRule BR-UDID-011 | Manufacturers based outside the EU need an authorised representative with an active mandate in EUDAMED. | Check the mandate in EUDAMED and have it confirmed. |
| What EUDAMED reports | Cause | Solution |
|---|---|---|
| Version does not matchRules BR-DTX-UDI-036 and BR-DTX-UDI-037 | An update requires the correct version number. With 0, EUDAMED counts up by itself, otherwise the current version plus 1 applies. A UDI-DI can only be updated if its latest version is registered. | Take the version number from the EUDAMED download and complete any open versions first. |
| Field must not changeRule BR-DTX-UDID-093 | Quantity, latex, single use, number of reuses, sterile, sterilisation, reprocessing and the Annex XVI indication stay the same in an update. | Assign a new UDI-DI for such changes. To find out when this is required, see Basic UDI-DI and UDI-DI. |
| Countries cannot be changed via the updateERR-BR-DTX-UDI-105.01 From upload sessions, rule BR-DTX-UDI-105 | Countries are changed via the separate service “Update Market Information”. The UDI-DI update can only change the first country. | Upload the country file as a separate step before the update. |
| Countries missing in the updateERR-BR-DTX-UDID-103.1 From upload sessions | In our upload sessions, this message appeared when an update submission contained only the changed data. A related rule is BR-DTX-UDI-103: the first country must be in the latest country list. | Include all data from the registered record and change only the affected data. |
| Country duplicated or not permittedRules BR-DTX-UDI-097, -098 and -100 | One country version per UDI-DI is permitted per message. Each country may only appear once. Only EU countries are permitted. | Clean up the country list for each affected item. |
An open draft still exists in EUDAMED for the affected item.
The response file shows you which other items in the same file have already been accepted. These are registered.
After each upload, EUDAMED generates a response file. It shows you for each item whether the registration was successful or there is an error.
These items are already registered.
Correct the affected data and resend only these items.
If the error affects the entire file, correct it and upload it again.

Many causes of errors can already be identified during preparation. Three checks help you do this.
Check every XML file against the current EUDAMED XSD before uploading.
Check codes, check digits, version numbers and countries against the business rules. Also consider the codes from HIBCC, IFA and ICCBBA, whose format EUDAMED only partially checks.
Compare your item list with the current download from EUDAMED. This protects data that is already registered and takes the existing data into account for updates.
The Trautmann UDI-Manager carries out these three checks. We also use our software to prepare your EUDAMED registration.
In the joint upload session, you upload with your own access. We support you personally, read in the responses and clarify them directly with you.
What else you may want to know about handling responses.
That depends on whether individual items or the entire file were rejected.
If individual items contain errors, correct the affected data and resend only these items. Accepted items are already registered.
If the entire file violates the schema, correct the file and upload it again as a whole.
Open “Data transfer” and then “Bulk Upload”. In the overview of your uploads, you will find the response file in the “Response” column as an XML file to download.
The business rules are published in the EUDAMED Information Centre in separate documents for general rules and product data. The schema is available as XSD files.
The explanations on this page for codes with the prefix “ERR-” and numbers such as M-50000 are based on our experience from joint upload sessions.
Often an unchanged data item is missing or the version number does not match. An update submission needs all data from the registered record with the correct version number.
Countries are changed via a separate service.
swissdamed accepts files in the EUDAMED format and has its own requirements: product data only, a maximum of 300 entries per file and exactly one Basic UDI-DI with one UDI-DI per entry.
To find out what you need to consider when registering in Switzerland, see swissdamed registration.
Send us your response file from EUDAMED. We will explain the error codes and show you which data you need to correct.
If you would like support with your registration, we will check your item list, create the upload files and support you personally during the upload.
We will agree with you on how to send us your response file.